China Real-time monitoring system for transmission line anti-icing - China Supplier China Real-time monitoring system for transmission line anti-icing - China Supplier China Real-time monitoring system for transmission line anti-icing - China Supplier China Real-time monitoring system for transmission line anti-icing - China Supplier China Real-time monitoring system for transmission line anti-icing - China Supplier

Real-time monitoring system for transmission line anti-icing

¥80000
Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards


Contact Info
  • Building C-9, Floor C, Precision达 Industrial Park, No.39 Qingfeng Avenue, Longgang Sub-district, Longgang District, Shenzhen City, 518116
  • 李女士
  • 13682351635
  • 1920671927@qq.com

Product Aliases: Transmission Line Ice Coverage Monitoring System, Transmission Line Ice Coverage Automatic Observation System, Transmission Line Ice Coverage Early Warning Monitoring Device

Product Model: TLKS-PMG-FB100

Transmission Line Anti-Icing Real-Time Monitoring System




I. Product Description:

Transmission Line Anti-Icing Real-Time Monitoring System It combines image processing technology and Internet of Things technology, and is mainly used for real-time monitoring of ice coverage on transmission lines and iron towers. It processes these images through a built-in image processing unit. The processing steps include image preprocessing, feature extraction, and status judgment. Through these technologies, the device can automatically identify and analyze ice-covered areas, and accurately determine the ice coverage status, so as to better carry out management and maintenance work. This greatly improves management efficiency and reduces the cost and risk of manual inspection.




II. Working Principle:

Transmission Line Anti-Icing Real-Time Monitoring System The working principle mainly includes the following steps:

1. Image Acquisition: Collect real-time image information of transmission lines and iron towers through the installed high-definition camera.

2. Image Processing: For the collected images, the system uses digital image processing technology for identification and analysis, including image enhancement, edge detection, threshold segmentation and other processing methods, to highlight and extract ice-covered areas.

3. Feature Extraction: Based on image processing, the system further extracts feature information of ice-covered areas, such as the shape, size, position, color, etc. of the ice coverage.

4. Status Judgment: Based on the extracted feature information, the system judges the status and identifies the ice coverage status of transmission lines and iron towers.

5. Early Warning and Alarm: Once the ice coverage status exceeds the safety threshold, the system will immediately send an early warning or alarm signal to notify the management personnel to deal with it in time.

6. Data Storage and Analysis: The system will also store the monitored images and data, and conduct regular analysis to evaluate the development trend and possible impact of ice coverage.

Through the above working principles,Transmission Line Anti-Icing Real-Time Monitoring System can realize real-time monitoring of transmission lines and iron towers, timely detect ice coverage problems and take corresponding measures, ensuring the safe and stable operation of the power system.




III. Product Functions:

1. It has the functions of managing and self-checking its own working status, including collection, storage, processing, communication, etc.

2. When it is judged that the device has a running fault, it can take corresponding measures to restore the normal running status of the device.

3. It has the functions of identity authentication and remote program update, with a complete update mechanism and methods.

4. It has the ability to modify parameters such as collection frequency, sampling time interval, network adapter address, etc. according to remote instructions

5. It has the ability to dynamically respond to remote instructions such as time query, setting, data request, and reset.

6. It can enter the remote debugging mode according to remote instructions, and output relevant debugging information.

7. It is equipped with a security chip, which can encrypt data, and access the platforms of provincial companies.




IV. Technical Parameters:

1. Power Supply Method: Solar energy plus battery

2. Communication Requirements: Support wireless network communication, and operators can be selected according to on-site conditions

3. Working Voltage: DC12V

4. Standby Duration: >30 days

5. Backend Software Platform:

6. Support access to Provincial and Municipal Bureau PMS Systems

7. PG Client/ Mobile Client to view monitoring data in real time

8. Remote update, configuration and debugging of front-end device parameters




V. Summary:

Transmission Line Anti-Icing Real-Time Monitoring System It can improve the operation efficiency and safety of the power grid, ensuring the stable operation of the power system. The device has functions such as automatic identification and analysis of ice-covered areas, early warning and alarm, data storage and analysis, which facilitates management and maintenance work. At the same time, the remote monitoring function allows management personnel to access monitoring data and control equipment at any time, further improving management efficiency. In short,Transmission Line Anti-Icing Real-Time Monitoring System is an important tool to ensure the safe and stable operation of the power grid, with broad application prospects and value.

We look forward to cooperating with you to jointly explore the market and provide high-quality products and services for customers. Contact Ms. Li from Telkom at: 13682351635  Landline: 0755-29500762

For customized products, the quoted price is a reference range price at the time of current market release, and the actual price is subject to negotiation.







VI. Notes:

1. Pay attention to avoiding the device from falling on the ground or being subjected to strong impact from other objects;

2. Pay attention to avoiding strong external impact on the solar panel, which may cause damage to the solar panel;

3. When installing, try to orient the solar panel towards the sun;

4. When installing the device, turn off the power switch, and turn on the power switch after installation is completed;

5. It is strictly prohibited to disassemble the structure or circuit board without permission. Unauthorized disassembly of the device will void the warranty.

Instruments & Meters/Measurement Standards/Electromagnetic Metrology Standards
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright © Toocle.com. All Rights Reserved.
(浙)-经营性-2023-0192
ChatGlobal TChat